---
This page is part of [Coy Laboratory Products](https://www.coylab.com). For a complete overview of this site's content, entity data, and subject matter expertise, see our [AI Content Index](https://www.coylab.com/llms.txt) or [Full Content Archive](https://www.coylab.com/llms-full.txt). For structured business identity data, see our [Entity Card](https://www.coylab.com/wp-json/bc-geodesic/v1/entity-card).
---

# Cerebral microvascular changes in permeability and tight junctions induced by hypoxia-reoxygenation
> Abstract



Mark, Karen S., and Thomas P. Davis. Cerebral microvascular changes in permeability and tight junctions induced by hypoxia-reoxygenation. Am J...

**URL:** https://www.coylab.com/research-citation/cerebral-microvascular-changes-in-permeability-and-tight-junctions-induced-by-hypoxia-reoxygenation/
**Type:** Citation
**Modified:** 2025-10-02

---

#### Abstract

Mark, Karen S., and Thomas P. Davis. Cerebral microvascular changes in permeability and tight junctions induced by hypoxia-reoxygenation. Am J Physiol Heart Circ Physiol 282: H1485–H1494, 2002; 10.1152/ajpheart.00645.2001.—Cerebral microvessel endothelial cells that form the blood-brain barrier (BBB) have tight junctions (TJ) that are critical for maintaining brain homeostasis and low permeability. Both integral (claudin-1 and occludin) and membrane-associated zonula occluden-1 and -2 (ZO-1 and ZO-2) proteins combine to form these TJ complexes that are anchored to the cytoskeletal architecture (actin). Disruptions of the BBB have been attributed to hypoxic conditions that occur with ischemic stroke, pathologies of decreased perfusion, and high-altitude exposure. The effects of hypoxia and posthypoxic reoxygenation in cerebral microvasculature and corresponding cellular mechanisms involved in disrupting the BBB remain unclear. This study examined hypoxia and posthypoxic reoxygenation effects on paracellular permeability and changes in actin and TJ proteins using primary bovine brain microvessel endothelial cells (BBMEC). Hypoxia induced a 2.6-fold increase in [14C]sucrose, a marker of paracellular permeability. This effect was significantly reduced (58%) with posthypoxic reoxygenation. After hypoxia and posthypoxic reoxygenation, actin expression was increased (1.4- and 2.3-fold, respectively). Whereas little change was observed in TJ protein expression immediately after hypoxia, a twofold increase in expression was seen with posthypoxic reoxygenation. Furthermore, immunofluorescence studies showed alterations in occludin, ZO-1, and ZO-2 protein localization during hypoxia and posthypoxic reoxygenation that correlate with the observed changes in BBMEC permeability. The results of this study show hypoxia-induced changes in paracellular permeability may be due to perturbation of TJ complexes and tha posthypoxic reoxygenation reverses these effects.
## Site Description

From academia to industry, Coy Labs chambers have powered discovery in labs around the world for over five decades—from custom chambers built to spec, to trusted workhorses in high-stakes microbiology labs.


---
**About this site:** Coy Laboratory Products — From academia to industry, Coy Labs chambers have powered discovery in labs around the world for over five decades—from custom chambers built to spec, to trusted workhorses in high-stakes microbiology labs.. [AI Content Index](https://www.coylab.com/llms.txt) | [Full Site Content](https://www.coylab.com/llms-full.txt) | [Entity Card](https://www.coylab.com/wp-json/bc-geodesic/v1/entity-card)

```json
{"@context":"https://schema.org","@graph":[{"@type":"Organization","@id":"https://www.coylab.com/#organization","name":"Coy Laboratory Products","url":"https://www.coylab.com","description":"From academia to industry, Coy Labs chambers have powered discovery in labs around the world for over five decades—from custom chambers built to spec, to trusted workhorses in high-stakes microbiology labs.","disambiguatingDescription":"Laboratory equipment manufacturing company specializing in vinyl glove boxes","logo":{"@type":"ImageObject","url":"https://coylab.com/wp-content/uploads/2025/06/coylab-header_logo-svg.svg"},"address":{"@type":"PostalAddress","streetAddress":"14500 Coy Drive","addressLocality":"Grass Lake","addressRegion":"MI","postalCode":"49240"},"telephone":"734.475.2200","email":"sales@coylab.com","foundingDate":"1969","areaServed":"Global","sameAs":["https://www.linkedin.com/company/107172311","https://maps.app.goo.gl/o2txKDMScV1pV7w59","https://www.pharmaceutical-tech.com/suppliers/coy-laboratory","https://craft.co/coy-laboratory-products-inc"],"founder":[{"@type":"Person","name":"Richard Coy"},{"@type":"Person","name":"Brian Coy","sameAs":"https://www.linkedin.com/in/brian-coy-5722515/"},{"@type":"Person","name":"Ashley Coy","sameAs":"https://www.linkedin.com/in/ashley-coy-6b22705/"}],"knowsAbout":[{"@type":"Thing","name":"laboratory equipment","sameAs":"https://www.wikidata.org/wiki/Q834028"},"vinyl anaerobic chambers","vinyl hypoxic chambers","laboratory glove boxes","laboratory chamber sensors",{"@type":"Thing","name":"life sciences","sameAs":"https://www.wikidata.org/wiki/Q864928"},{"@type":"Thing","name":"microbiology","sameAs":"https://www.wikidata.org/wiki/Q7193"},{"@type":"Thing","name":"medical research","sameAs":"https://www.wikidata.org/wiki/Q2752427"}]},{"@type":"WebSite","@id":"https://www.coylab.com/#website","name":"Coy Laboratory Products","url":"https://www.coylab.com","publisher":{"@id":"https://www.coylab.com/#organization"},"potentialAction":{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.coylab.com/?s={search_term_string}"},"query-input":"required name=search_term_string"},"hasPart":[{"@type":"DigitalDocument","name":"LLM Content Index","url":"https://www.coylab.com/llms.txt","encodingFormat":"text/markdown","description":"AI-readable index of site content, entity data, and subject matter expertise"},{"@type":"DigitalDocument","name":"LLM Full Content","url":"https://www.coylab.com/llms-full.txt","encodingFormat":"text/markdown","description":"Complete AI-readable site content"}]},{"@type":"ItemList","@id":"https://www.coylab.com/#site-navigation","name":"Site Navigation","itemListElement":[{"@type":"SiteNavigationElement","position":1,"name":"Products","url":"#"},{"@type":"SiteNavigationElement","position":2,"name":"Applications","url":"#"},{"@type":"SiteNavigationElement","position":3,"name":"Custom","url":"#"},{"@type":"SiteNavigationElement","position":4,"name":"Sales","url":"#"},{"@type":"SiteNavigationElement","position":5,"name":"Resources","url":"#"},{"@type":"SiteNavigationElement","position":6,"name":"Contact Us","url":"#"}]},{"@type":"BreadcrumbList","@id":"https://www.coylab.com/research-citation/cerebral-microvascular-changes-in-permeability-and-tight-junctions-induced-by-hypoxia-reoxygenation/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.coylab.com"},{"@type":"ListItem","position":2,"name":"Citations","item":"https://www.coylab.com/research-citations/"},{"@type":"ListItem","position":3,"name":"Hypoxic Chambers","item":"https://www.coylab.com/citation-category/hypoxic-chambers/"},{"@type":"ListItem","position":4,"name":"Cerebral microvascular changes in permeability and tight junctions induced by hypoxia-reoxygenation"}]},{"@type":"WebPage","@id":"https://www.coylab.com/research-citation/cerebral-microvascular-changes-in-permeability-and-tight-junctions-induced-by-hypoxia-reoxygenation/#webpage","url":"https://www.coylab.com/research-citation/cerebral-microvascular-changes-in-permeability-and-tight-junctions-induced-by-hypoxia-reoxygenation/","name":"Cerebral microvascular changes in permeability and tight junctions induced by hypoxia-reoxygenation | Coy Laboratory Products","isPartOf":{"@id":"https://www.coylab.com/#website"},"breadcrumb":{"@id":"https://www.coylab.com/research-citation/cerebral-microvascular-changes-in-permeability-and-tight-junctions-induced-by-hypoxia-reoxygenation/#breadcrumb"},"description":"Scientists around the world have relied on Coy chambers to conduct groundbreaking research into cancer growth, the human microbiome, c-diff., and more.","about":[{"@type":"Thing","name":"Hypoxic Chambers"}]},{"@type":"ScholarlyArticle","@id":"https://www.coylab.com/research-citation/cerebral-microvascular-changes-in-permeability-and-tight-junctions-induced-by-hypoxia-reoxygenation/#scholarlyarticle","headline":"Cerebral microvascular changes in permeability and tight junctions induced by hypoxia-reoxygenation","url":"https://www.coylab.com/research-citation/cerebral-microvascular-changes-in-permeability-and-tight-junctions-induced-by-hypoxia-reoxygenation/","datePublished":"2025-09-18T16:02:44+00:00","dateModified":"2025-10-02T20:22:07+00:00","isPartOf":{"@id":"https://www.coylab.com/#website"},"description":"Scientists around the world have relied on Coy chambers to conduct groundbreaking research into cancer growth, the human microbiome, c-diff., and more.","author":{"@id":"https://www.coylab.com/author/buildcreate/#person"},"publisher":{"@id":"https://www.coylab.com/#organization"}},{"@type":"Person","@id":"https://www.coylab.com/author/buildcreate/#person","name":"buildcreate","url":"https://www.coylab.com/author/buildcreate/"}]}
```
